Loading...
Loading...

Specialist tribology and transformer-oil analysis since 2024, built on decades of combined expertise in condition monitoring.
June 2024
Tribology
Northern Europe
CVR
44924544 · Consulting engineering firm (rådgivende ingeniørvirksomhed)
Registered address
Lokesvej 9F, 4., 8230 Åbyhøj, DenmarkTriboTech was founded in 2024 by two specialists with more than 50 years of combined experience — in a specialist discipline that critical infrastructure quietly depends on.
Co-founder & Market Director
Hans Møller has spent more than four decades in energy — from mechanical coal sampling in the 1980s and power-plant chemistry into applied tribology and the condition monitoring of offshore wind fleets and 400 kV transformers. His foundation is the Theory of Sampling: a result is never better than the sample behind it — the principle underneath everything TriboTech does with oil and grease. He takes full ownership of every project he runs, and clients rely on that and on the long-term relationships he builds and keeps. He stays in it because the work is specialist, often overlooked, and matters to the infrastructure it protects.
Co-founder & Managing Director
Jesper Vinther came to tribology from research science. He holds an M.Sc. in process engineering and a Ph.D. in nanotechnology from Aarhus University, where his work centred on surface engineering and electrochemistry — the surface science that underpins lubrication and wear. He has held research stints at Caltech and DTU, has peer-reviewed publications to his name, and is a co-inventor on patent application WO/2020/173822. He is a Certified Lubrication Specialist (CLS) for tribology and oil analysis, and he chairs Danish Standard committee S-510 (IEC fluids for electrotechnical applications) — the role he took over from Hans. Trained in the Theory of Sampling under Kim H. Esbensen, he co-developed TriboTech's grease-analysis method for early bearing-failure detection and turns analytical data into recommendations clients can act on.
TriboTech ApS is a specialized Danish consultancy firm in applied tribology, established in June 2024. We provide expert analysis and advisory services for lubricating oils, grease, transformer oil, and coolants.
Our team brings together decades of experience in tribology, combining technical excellence with practical industry knowledge. We focus on delivering actionable insights that help our clients optimize their maintenance strategies and extend equipment life.
We are committed to supporting the reliability and efficiency of critical infrastructure across Northern Europe, helping our clients achieve operational excellence through data-driven decision making.
We maintain and develop our technical expertise and stay up to date with tribology advancements
We build long-term relationships based on trust, transparency, and shared success
Our focus is on delivering measurable improvements in reliability, efficiency, and cost savings
Operating from our base in Åbyhøj, Denmark, we work to documented internal procedures. Analytical work is carried out by our partner laboratories.
Building on decades of combined expertise to create the future of tribology consultancy
Established in Åbyhøj, Denmark with a vision for excellence in tribology consultancy
Analytical work carried out by our partner laboratories
Implemented procedures based on the principles of IEC, ISO and ASTM
Expanded collaboration with on-site service providers for comprehensive maintenance solutions
Predictive maintenance and standards-based diagnostics in freely available tools
Our work rests on named professional qualifications and on procedures based on the principles of the standards named below.
Our lead consultant holds the CLS certification from STLE.
Issued by the Society of Tribologists and Lubrication Engineers (STLE). The credential is personal and can be verified on Credly.
Verify on CredlyOur lead consultant chairs the Danish Standards committee S-510.
Our lead consultant is a member of CIGRE.
Our procedures and our diagnostic tools are based on the principles of the standards named below. Naming a standard states our working basis; it is not a claim of certification, accreditation or approval by any third party.
Interpretation of dissolved and free gases — the basis of our ratio analysis.
Source of the Duval Triangle 1 fault-zone boundaries. Our Pentagon 1 and 2 zone geometry follows the CIGRE ICTRAM06-2023 corrected coordinates.
DGA interpretation. We apply its Triangle 4/5 sequencing rule and its multiple-fault rule; the ±15 %/±30 % analytical-uncertainty figures are IEC 60599:2022 Cl. 6.2 (defined at 10 × S and 5 × S, S = the analytical detection limit).
Supervision and maintenance of mineral insulating oils — the basis of our oil-condition assessment.
Sampling of free gases, and analysis of free and dissolved gases — the basis of our gas-extraction procedures.
Sampling of insulating liquids — the basis of our field sampling procedure.
TriboTech is a consulting engineering company and does not operate its own testing laboratory. Analysis is placed with a laboratory that works to documented laboratory procedures.
Documentation for the qualification named above is available on request.
Every hour of downtime costs thousands. Urgent transformer oil (mineral oil) analysis – DGA and fluid properties – can be delivered in 48 hours by agreement, subject to laboratory capacity.
25+ critical-infrastructure clients currently served